Use
Ensures a better continuity of service to unattended electrical installations.
Limits the number and the cost of on-site interventions.

Applications
Telecommunication and broadcasting.
Pumping and water treatment.
Street lighting and road signs.
Agriculture.
Banks, computing.

Technical features

   Dimensions
H 210 mm x L 73 mm x P 90 mm
   Weight
1,3 Kg
   Installation
Pluggable on a support screwed on the board of the circuit-breaker
   Connection
Removable 2 wires power cord - 1.5 m
   Use
With Schneider 2 or 4 pole circuit-breaker
   Power supply
230 VAC / 48 VDC / 24 VDC / 12 VDC
   Waking state consumption
25 mA sous 230 VAC
   Indicator lamps
Green : in use - flashing red : fault - yellow : battery status
   Internal battery
12 V - 1,2 AH (duration 5 years)
   Autonomy in case of fault
5 days
   Internal protection
2,5 kA varistor + 6,3 A fuse
   Duration of switch on
# 2 s
   Maximum motor torque
1 Nm
   Rotation speed of motor mechanism
6,6 rotation/mn
   Remote processing connection *
Unpluggable screw terminal block
   Remote control inputs *
C/O contacts insulation by opto isolator
   Remote control consumption *
20 mA
   Remote control impulse *
Closing of contact > 1 s
   Alarm report output *
2 relays 250 VAC, 30 VDC, 5 A sigle side stable (2 pts)
   Impulse counter *
LCD 6 digits with reset (retention > 10 years)
   Time delay *
Adjustable from 6 s to 10 h
   Shunt trip *
By solenoïd drive 60 W - 0,6kg
   Operating temperature 
25° C à + 50° C
   Working safety
Switch off when people are on site
   Protection index
IP 21
* optional

Operating characteristics of the RDB90
In case of tripping due to a sharp fault (short-circuit or earth fault) only one test is made.
In other cases (overcurrent, overvoltage, temporary fault) three tests are made before the equipment becomes faultyt.
This cycle restarts after 5 minutes without tripping.
The box and the cord can be unplugged to allow maintenance under voltage and without the use of any tool.
The battery state is indicated by indicator lamp and contact.


Part number

   
 With battery
 Without battery
   
 230 VAC
 230 VAC
 48 VDC
 24 VDC
 12 VDC
 Standard
11000
12000
13000
14000
15000
   Timing (6s to 10 h)
11001
12001
13001
14001
15001
   Timing + counter
11003
12003
13003
14003
15003
   Remote control
11005
12005
13005
14005
15005
   Remote control + timing
11006
12006
13006
14006
15006
   Remote control + timing + counter
11008
12008
13008
14008
15008
   Remote control + shunt trip
11015
12015
13015
14015
15015
   Remote control + shunt trip + timing +  counter
11018
12018
13018
14018
15018
 
RDB 90 / Automatic recloser for circuit breaker